Explosion-proof display – XDP

Explosion-proof display – XDP

The XDP explosion-proof display provides the measurement of percent or ppm oxygen or hydrogen gas. The explosion-proof XDP is certified for use in Class 1, Division 1, Groups B, C and D as well as Zone 1 ATEX/IECEX Ex d IIC T6 Gb hazardous areas. The XDP features advanced microprocessor-based electronics, a magnetic, through-the-glass keypad, a universal power supply (magnetic), one 0/4 to 20 mA or 0 to 2 VDC analog output, four process alarms, and a fault alarm.

Features

  • Explosion-proof for Class I, Division 1, Group B, C and D hazardous areas, Nema 4X
  • Flameproof for ATEX II 2 G Ex d IIC T6 Gb IECEX Ex d IIC T6 Gb IP66
  • Magnetic through-the-glass keypad
  • Universal AC input, Optional 24VDC input
  • 24 VDC power supply for XMO2, XMTC or OXY.IQ
  • Software for measurement of percent or ppm oxygen or hydrogen
  • Three-curve software for hydrogen-cooled generator
  • Programmable process relay contacts

Specification

Input power  : 85 to 264 VAC, 47 to 63 Hz, 40 W, 24 VDC(±0.2V), 40W
Output power supply  : 24 VDC ±2 VDC at 1.2 Amp
Display  : Four-line, backlit liquid crystal display
Display accuracy  : ±0.25% of full scale

Below listed are the related files that can be downloaded to you PC. All the files are in PDF format.